Related Experiment Video
Updated: Jul 7, 2025

Production and Analysis of Sporosarcina pasteurii Biocement Bricks Using Custom 3D-Printed Molds for Unconfined Compression Tests
Published on: March 7, 2025
Preparation and Compression Resistance of Lightweight Concrete Filled with Lightweight Calcium Carbonate Reinforced
Erke Wang1,2, Lixue Xiang2, Bo Tang2
1Shanghai Key Laboratory of Engineering Materials Application and Evaluation, China Shanghai Thermophysical Properties Big Data Professional Technical Service Platform, Shanghai Engineering Research Center of Advanced Thermal Functional Materials, School of Energy and Materials, Shanghai Polytechnic University, Shanghai 201209, China.
Abstract:
Lightweight concrete is widely used in the construction industry due to its low density and high strength. In this paper, lightweight concrete was prepared by a simple two-step method. Firstly, the light calcium carbonate reinforced epoxy macrospheres (LCR-EMS) material was obtained by adhering calcium lighter carbonate powder to the expanded polystyrene foam spheres (EPS) material using the "balling method". In the second step, the LCR-EMS was mixed with water, cement, and the hollow glass microspheres (HGMS) material using the "molding method" to obtain lightweight concrete. The combination of macroscopic photographs and microscopic morphology shows that the LCR-EMS material itself is uniformly encapsulated and well bonded to the matrix. Test results show that the density of the lightweight concrete decreases with an increase in the volume fraction of stacked LCR-EMS, the diameter, and the proportion of HGMS in the matrix, but it decreases with a decrease in the number of layers of LCR-EMS. The compressive strength of lightweight concrete exhibits a completely opposite trend. When three layers of LCR-EMS were used as filler material, the density and compressive strength of the concrete were 1.246 g/cm3 and 8.19 MPa, respectively. The density and maximum compressive strength of lightweight concrete were 1.146 g/cm3 and 6.37 Mpa, respectively, when filled with 8-9 mm-2L-90 svol% of LCR-EMS and 40 wt% of HGMS in the matrix. Compared with lightweight concrete filled with 90% EPS, the density increased by 20% while the compressive strength increased by 300%.
Related Concept Videos
Fiber Reinforced Concrete
Pozzolans
Fly ash is...
Additives and Fillers in Concrete
The...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Reinforcements in Concrete
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...

