Determination of formaldehyde in textile dye and auxiliary chemicals with headspace gas chromatography-flame
Korel Güneş1,2, Ziya Can1, Ayşem Arda1
1Department of Chemistry, Faculty of Engineering, İstanbul University - Cerrahpaşa, İstanbul, Turkey.
Abstract:
Formaldehyde is a chemical used in many different industrial sectors and is classified as a carcinogen as well as causing allergic reactions. Due to the health effects of formaldehyde, which is widely used in textile dyes and auxiliary chemicals, its analysis in this type of matrices becomes important. In this study, in order to meet these requirements, formaldehyde was converted to oxime derivative by derivatization with o-(2,3,4,5,6-Pentafluorobenzyl)hydroxylamine hydrochloride. This derivative was successfully sampled with the headspace technique and analyzed with a gas chromatography-flame ionization detector (GC-FID). For the developed method, derivatization and salt effect parameters were investigated. For the method, the limit of detection (LOD) was found as 0.05 mg L-1 and real sample analyzes were made for different types of dyes used in the textile industry, and sodium naphthalene sulfoxylate formaldehyde. In addition, the developed method was validated with sodium naphthalene sulfoxylate formaldehyde against ISO 14184-1 method by applying student t-, F-tests and no difference was found in terms of accuracy and precision. Thus, the applicability of the developed method to dyes and auxiliary chemicals used in the textile industry was successfully demonstrated. This allows all quality control processes to be handled using only one method.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Flame Photometry: Lab
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....