Trunnionosis in Metal-on-Polyethylene Total Hip Arthroplasty With Periprosthetic Infection: A Case Report
Related Experiment Video
Updated: Jul 7, 2025

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
Fumito Kobayashi1, Kenichi Oe1, Shohei Sogawa1
1Department of Orthopaedic Surgery, Kansai Medical University, Hirakata, JPN.
Abstract:
A 67-year-old man who underwent right hemiarthroplasty and left total hip arthroplasty (THA) experienced left hip pain two years previously. No previous diagnosis was made at other hospitals. Radiography revealed left hip trunnionosis because of stem-neck shortening, with periprosthetic joint infection (PJI) spreading to both hips. Bilateral revision THA was performed, but the treatment was difficult due to the delayed diagnosis, necessitating the extraction of the well-fixed stem for PJI. Trunnionosis is caused by implant-related, surgical, and patient factors, and early diagnosis is important because of its association with PJI. Furthermore, even implants with few reports of trunnionosis can lead to this complication. Surgeons should always consider that performing THA using a large-diameter head predisposes the patient to trunnionosis.