Related Experiment Video
Updated: Jul 7, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Comparison of H*(10) estimations, due to neutrons and γ-rays, around FANT with two 241Am/9Be sources
Lenin E Cevallos-Robalino1, Gonzalo García-Fernández2, Eduardo Gallego2
1Carrera de Ingeniería Electrónica, Grupo de Investigación en Micro-Nanotecnología y Energía Nuclear (NANOTECH), Universidad Politécnica Salesiana (UPS), C. Robles 107 Chambers, 090108, Guayas, Guayaquil, Ecuador.
Abstract:
FANT (Fuente Ampliada de Neutrones Térmicos; in Spanish) is a thermal neutron irradiation facility with an extended and very uniform irradiation area, which has been developed by the Neutron Measurement Laboratory of the Energy Engineering Department at Universidad Politécnica de Madrid (LMN-UPM). In FANT, an isotopic neutron source (241Am/9Be) produces the primary neutrons. The design and facility optimization were carried out by extensive Monte Carlo calculations. In addition, Monte Carlo methods were used to evaluate the facility's performance to produce a constant and uniform thermal neutron field; these results were validated through experimental methods. FANT is designed to have two neutron sources; the objective of this work is to estimate the ambient dose equivalent due to neutrons and gamma-rays by Monte Carlo methods, and to compare these values with measured experimental doses. Thus, the performance of FANT with the two 241Am/9Be sources of LMN-UPM, with regard to the ambient dose equivalent H*(10) produced by both neutrons and photons around the facility, is analyzed in this work. The results are compared with those previously obtained in the framework of the results obtained with the LB6411 device around FANT.
More Related Videos
10:10Neutron Crystallography Data Collection and Processing for Modelling Hydrogen Atoms in Protein Structures
Published on: December 1, 2020
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Related Concept Videos
Nuclear Transmutation
Atomic Nuclei: Nuclear Spin State Population Distribution
High-Resolution Mass Spectrometry (HRMS)
Biological Effects of Radiation
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...
Isotopes and Radioisotopes
An isotope containing...