Fabrication and evaluation of a molecular-imprinted-polymer functionalized electrode for selective electric
Jiangyi Wu1, Lingxin Zheng1, Xiaojia Huang1
1Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, Key Laboratory of the Ministry of Education for Coastal and Wetland Ecosystems, College of the Environment and Ecology, Xiamen University, Xiamen, 361005, China.
Abstract:
Specific extraction and separation plays a pivotal role in the accurate quantification of trace phytohormones (PHs). However, due to their high polarity, specific capture of PHs is challenging. In this study, under the assistance of electric field, a molecular-imprinted-polymer functionalized electrode (MIP@ED) was in-situ prepared using 3-indoleacetic acid (IAA) as template and employed as the adsorbent of electric field-assisted solid-phase microextraction (EA-SPME) for specific capture of PHs. Results showed that the implementation of electric field during the preparation of MIP@ED and EA-SPME procedures improved the extraction selectivity, the selective factors towards IAA and its structural analogues increased from 2.09 to 2.45 to 2.88-3.51. Under the optimum conditions, the proposed MIP@ED/EA-SPME was combined with HPLC technique to monitor trace PHs in water and agricultural products. The achieved limits of detection were in the ranges of 0.0053-0.011 μg/L and 0.048-0.12 μg/kg for water and agricultural product, respectively. The established approach was successfully applied to quantify trace PHs in real samples, and the spiked recoveries varied from 84.0 % to 118 % with good repeatability (RSDs blow 10 %). The obtained results provided clear evidence that the developed approach employing the MIP@ED/EA-SPME technique demonstrated high sensitivity, good selectivity, satisfactory reproducibility and environmental friendliness in the quantification of trace PHs in complex samples. In addition, the current study supplied a new strategy to enhance the specific recognition performance of MIP-based SPME.
More Related Videos
09:33Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
08:03Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
Related Concept Videos
Potentiometry: Membrane Electrodes
Ion-Exchange Chromatography