Assessing the external validity and clinical relevance of umbilical doppler resistance index references in daily
Simon Crequit1, Gilles Grangé2, François Goffinet3
1Department of Gynecology and Obstetrics, Montreuil Hospital, Centre Hospitalier Intercommunal de Montreuil Maternity Unit, 56 Boulevard de la Boissière, Montreuil 93100, France.
Objective:
To assess the external validity and clinical relevance of current references for umbilical artery resistance index (UA RI) in daily practice.
Methods:
Retrospective cross-sectional single center study including all UA RI measurements between 22 and 40 gestational weeks (GW) from distinct patients between 2014 and 2022. Patients with normal pregnancies and normal neonatal outcomes that had an UA RI measurement between 2014 and 2019 were used to calculate reference ranges. The established reference for the 95th centile was compared to two current references. The clinical relevance of the established reference was tested by comparing neonatal outcomes according to the 95th percentile among the consecutive distinct patients between 2020 and 2022.
Results:
Among the 13342 consecutive distinct patients with a singleton pregnancy that had an UA RI measurement between 22 and 40 GW between 2014 and 2022, 5298 patients were included to establish the reference ranges, and 3634 patients to validate these ranges. For each gestational age, the established references were similar to current references. Using the established references, the proportion of patients presenting an UA RI>95th percentile among the patients with normal pregnancies in the validation population was comparable to the proportion when using the two current references. Among the validation population, 268 patients (7.4 %) (95%CI[6.5-8.2]) presented an UA RI ≥ 95th percentile. Of these 268 patients, 67.9% had a SGA newborn (versus 19.2%, p<0.001) and 59% a preterm birth (versus 13.9%, p<0.001).
Conclusions:
The reference range obtained from daily practice is clinically relevant and similar to current references.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement