Related Experiment Video
Updated: Aug 10, 2026

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
PEEK Interference Screws Show Significant Tunnel Enlargement After ACL Reconstruction and is Comparable to
Christian Coppola1, Sandra Krost1, Armin Runer1
1Department of Orthopaedics and Trauma Surgery, Medical University Innsbruck, Innsbruck, Austria.
Background:
It is unclear whether the use of polyetheretherketone (PEEK) interference screws for anterior cruciate ligament (ACL) reconstruction leads to postoperative tunnel enlargement. Femoral tunnel enlargement was further compared with adjustable-length loop cortical fixation.
Methods:
Eighteen patients with ACL reconstruction using hamstring grafts were retrospectively divided into two groups. Eleven patients were treated with the ACL reconstruction technique using a PEEK interference screw for femoral graft fixation. Seven patients received adjustable-length loop cortical buttons for femoral fixation. Tibial ACL graft fixation was performed using PEEK interference screws. Tunnel volume changes were assessed using computed tomography (CT) scans performed after surgery (100%) and after 1 year. The maximal tunnel diameter was measured.
Results:
The group with femoral screw fixation showed a mean tunnel volume change of 108.15 ± 13.7% on the tibial side and 124.07 ± 25.38% on the femoral side. The group with femoral button fixation showed a tunnel volume change of 111.12 ± 12.72% on the tibial side and 130.96 ± 21.71% on the femoral side. The differences in femoral tunnel volume changes were not significant (P = 0.562). Femoral tunnels with PEEK screw fixation showed significantly larger diameter after 12 months in comparison with button fixation (13.02 ± 1.43 mm vs. 10.46 ± 1.29 mm, P < 0.001).
Conclusions:
PEEK interference screws were associated with significant tibial and femoral tunnel enlargement. Femoral tunnel enlargement was comparable between PEEK interference screws and button fixation. Final femoral tunnel diameter was significantly larger with PEEK screw fixation in comparison to button fixation.
Related Concept Videos
Normal Strain under Axial Loading
Plastic Behavior
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Members Made of Elastoplastic Material
As the bending moment...
Plastic Deformations

