Related Experiment Video
Updated: Jul 6, 2025

Author Spotlight: Advancements in X-ray CT Tool Chain for Tree Core Analysis
Published on: September 22, 2023
Limited-View X-Ray Tomography Combining Attenuation and Compton Scatter Data: Approach and Experimental Results
Abdulla Desmal1, Jeffrey R Schubert2, Jeffrey Denker2
1Department of Electrical and Computer EngineeringTufts University Medford MA 02155 USA.
Abstract:
X-ray inspection systems are critical in medical, non-destructive testing, and security applications, with systems typically measuring attenuation along straight-line paths connecting sources and detectors. Computed tomography (CT) systems can provide higher-quality images than single- or dual-view systems, but the need to measure many projections leads to greater system cost and complexity. Typically, off-angle Compton scattered photons are treated as noise during tomographic inversion. We seek to maximize the image quality of limited-view systems by combining attenuation data with measurements of Compton-scattered photons, exploiting the fact that the broken-ray paths followed by scattered photons provide additional geometric sampling of the scene. We describe a single-scatter forward model for Compton-scatter data measured with energy-resolving detectors, and demonstrate a reconstruction algorithm for density that combines both attenuation and scatter measurements. The experimental results suggest that including Compton-scattered data in the reconstruction process can improve image quality for density reconstruction using limited-view systems.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
09:47Array Tomography Workflow for the Targeted Acquisition of Volume Information using Scanning Electron Microscopy
Published on: July 15, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...