Advancing acceptance: assessing acceptance of the ESR iGuide clinical decision support system for improved computed
Clara Singer1, Osnat Luxenburg2, Shani Rosen1
1Research Center for Medical Technology Policy and Innovation, The Gertner Institute for Epidemiology and Health Policy Research, The Chaim Sheba Medical Center, Tel Hashomer, Ramat Gan, Israel.
Background:
A clinical decision support system (CDSS), the European Society of Radiologists (ESR) iGuide, was developed to address gaps in the availability and use of effective imaging referral guidelines.
Aim:
This study aimed to assess the appropriateness of computed tomography (CT) exams with and without ESR iGuide use, as well as the usability and acceptance of the physician systems.
Methods:
A retrospective single-center study was conducted in which data from 278 consecutive CT tests referred by physicians were collected in the first phase (T1), and physicians used the ESR iGuide system for imaging referrals in the second phase (T2; n = 85). The appropriateness of imaging referrals in each phase was assessed by two experts, and physicians completed the System Usability Scale.
Results:
The mean appropriateness level on a scale of 0-9 was 6.62 ± 2.69 at T1 and 7.88 ± 1.4 at T2. When using a binary variable (0-6 = non-appropriate; 7-9 = appropriate), 70.14% of cases were found appropriate at T1 and 96.47% at T2. Surgery physician specialty and post-intervention phase showed a higher likelihood of ordering an appropriate test (p = 0.0045 and p = 0.0003, respectively). However, the questionnaire results indicated low system trust and minimal clinical value, with all physicians indicating they would not recommend collegial use (100%).
Conclusion:
The study suggests that ESR iGuide can effectively guide the selection of appropriate imaging tests. However, physicians showed low system trust and use, indicating a need for further understanding of CDSS acceptance properties. Maximizing CDSS potential could result in crucial decision-support compliance and promotion of appropriate imaging.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...