Related Experiment Video
Updated: Jul 6, 2025

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Mapping Injection Order Messages to Health Level 7 Fast Healthcare Interoperability Resources to Collate Infusion
Shunsuke Doi1, Shinichiroh Yokota1, Yugo Nagae1
1Department of Healthcare Information Management, The University of Tokyo Hospital, Tokyo, Japan.
Background:
When administering an infusion to a patient, it is necessary to verify that the infusion pump settings are in accordance with the injection orders provided by the physician. However, the infusion rate entered into the infusion pump by the health care provider cannot be automatically reconciled with the injection order information entered into the electronic medical records (EMRs). This is because of the difficulty in linking the infusion rate entered into the infusion pump by the health care provider with the injection order information entered into the EMRs.
Objectives:
This study investigated a data linkage method for reconciling infusion pump settings with injection orders in the EMRs.
Methods:
We devised and implemented a mechanism to convert injection order information into the Health Level 7 Fast Healthcare Interoperability Resources (FHIR), a new health information exchange standard, and match it with an infusion pump management system in a standard and simple manner using a REpresentational State Transfer (REST) application programming interface (API). The injection order information was extracted from Standardized Structured Medical Record Information Exchange version 2 International Organization for Standardization/technical specification 24289:2021 and was converted to the FHIR format using a commercially supplied FHIR conversion module and our own mapping definition. Data were also sent to the infusion pump management system using the REST Web API.
Results:
Information necessary for injection implementation in hospital wards can be transferred to FHIR and linked. The infusion pump management system application screen allowed the confirmation that the two pieces of information matched, and it displayed an error message if they did not.
Conclusion:
Using FHIR, the data linkage between EMRs and infusion pump management systems can be smoothly implemented. We plan to develop a new mechanism that contributes to medical safety through the actual implementation and verification of this matching system.
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Routes of Drug Administration: Parenteral
The intravenous route (IV) of drug administration can be further categorized into two types. The bolus injection administers the entire dose rapidly, while an intravenous infusion slowly delivers smaller doses steadily.
The IV route is often...
Flow Sheet
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
Drug Delivery: Parenteral Route
There are three primary parenteral routes: intravenous (IV), intramuscular (IM), and subcutaneous (SC). The IV route introduces the drug directly into the bloodstream, ensuring immediate action. The IM route...
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process: