Importance of computed tomography in posterior malleolar fractures: Added information to preoperative X-ray studies
Noé De Marchi Neto1, Pietro Felice Tomazini Nesello2, Jordanna Maria Bergamasco2
1Department of Orthopedics and Traumatology of the São Paulo Mercy Hospital (Santa Casa de São Paulo)-Fernandinho Simonsen Pavillion, Faculdade de Ciências Médicas da Santa Casa de São Paulo-Brazil, São Paulo 01221-020, Brazil. noedemarchineto@gmail.com.
Background:
Ankle fractures are common lesions of the lower limbs. Approximately 40% of ankle fractures affect the posterior malleolus (PM). Historically, PM osteosynthesis was recommended when PM size in X-ray images was greater than 25% of the joint. Currently, computed tomography (CT) has been gaining traction in the preoperative evaluation of ankle fractures.
Aim:
To elucidate the similarity in dimensions and to correlate PM size in X-ray images with the articular surface of the affected tibial plafond in the axial view on CT (AXCT) of a PM fracture.
Methods:
Eighty-one patients (mean age: 39.4 ± 13.5 years) were evaluated (54.3% were male). Two independent examiners measured PM size in profile X-ray images (PMXR) and sagittal CT (SAGCT) slices. The correlation of the measurements between the examiners and the difference in the PM fragment sizes between the two images were compared. Next, the PM size in PMXR was compared with the surface of the tibial plafond involved in the fracture in AXCT according to the Haraguchi classification.
Results:
The correlation rates between the examiners were 0.93 and 0.94 for PMXR and SAGCT, respectively (P < 0.001). Fragments were 2.12% larger in SAGCT than in PMXR (P = 0.018). In PMXR, there were 56 cases < 25% and 25 cases ≥ 25%. When PMXR was < 25%, AXCT corresponded to 10.13% of the tibial plafond. When PMXR was ≥ 25%, AXCT was 24.52% (P < 0.001). According to the Haraguchi classification, fracture types I and II had similar PMXR measurements that were greater than those of type III. When analyzing AXCT, a significant difference was found between the three types, with II > I > III (P < 0.001).
Conclusion:
PM fractures show different sizes using X-ray or CT images. CT showed a larger PM in the sagittal plane and allowed the visualization of the real dimensions of the tibial plafond surface.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...