Related Experiment Video
Updated: Jul 6, 2025

In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy
Published on: December 9, 2015
Radiation from the equine perineal region is low compared with the elbow and head 24 hours after bone scintigraphic
Leticia Marcelino1, Emma Falk2, Jessica Johansson1
1Department of Diagnostic Imaging, University Animal Hospital, Swedish University of Agricultural Sciences, Uppsala, Sweden.
Abstract:
The timing of follow-up radiography and ultrasound in horses that undergo skeletal scintigraphy for lameness investigation varies internationally and between equine hospitals. The prospective, one-group, pretest, posttest study aimed to estimate radiation levels from horses three and 24 h after injection of hydroxydiphosphonate labeled with metastable technetium (99mTc-HDP) and investigate which anatomical locations of the horse had higher radiation levels. Included were 46 horses referred for lameness investigation between June and December 2021. Radiation levels from the horse surface were measured using an electronic device from six anatomical locations (head, elbow, dorsum, ventrum, stifle, and perineum) at two time points and adjusted to three and 24 h after injection of 99mTc-HDP using the radioactive decay law. The radiation measured was significantly different in the various locations of the horses for both time points. At 3 h after injection of 99mTc-HDP, the ventrum had the highest radiation dose. At 24 h, the radiation emitted from the perineal region was significantly lower (P < .0001) than from the elbow and head, which had the highest values. There was a negative correlation between age and the radiation detected at 24 h postinjection (P = .02). Radiation from the perineal region was low compared with other regions of the horse 24 h postscintigraphy. Additional care should be taken around the ventrum area during the scintigraphy examination and around the elbow and head at 24 h postscintigraphy to minimize radiation to personnel.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Related Concept Videos
X-ray Imaging
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT