Related Experiment Video
Updated: Jul 6, 2025

Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs
Published on: May 12, 2017
Interpretation of field and LEAP potentials recorded from cardiomyocyte monolayers
Auriane C Ernault1, Rushd F M Al-Shama1, Jiuru Li2
1Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, Amsterdam, The Netherlands.
Abstract:
Multielectrode arrays (MEAs) are the method of choice for electrophysiological characterization of cardiomyocyte monolayers. The field potentials recorded using an MEA are like extracellular electrograms recorded from the myocardium using conventional electrodes. Nevertheless, different criteria are used to interpret field potentials and extracellular electrograms, which hamper correct interpretation and translation to the patient. To validate the criteria for interpretation of field potentials, we used neonatal rat cardiomyocytes to generate monolayers. We recorded field potentials using an MEA and simultaneously recorded action potentials using sharp microelectrodes. In parallel, we recreated our experimental setting in silico and performed simulations. We show that the amplitude of the local RS complex of a field potential correlated with conduction velocity in silico but not in vitro. The peak time of the T wave in field potentials exhibited a strong correlation with APD90 while the steepest upslope correlated well with APD50. However, this relationship only holds when the T wave displayed a biphasic pattern. Next, we simulated local extracellular action potentials (LEAPs). The shape of the LEAP differed markedly from the shape of the local action potential, but the final duration of the LEAP coincided with APD90. Criteria for interpretation of extracellular electrograms should be applied to field potentials. This will provide a strong basis for the analysis of heterogeneity in conduction velocity and repolarization in cultured monolayers of cardiomyocytes. Finally, a LEAP is not a recording of the local action potential but is generated by intracellular current provided by neighboring cardiomyocytes and is superior to field potential duration in estimating APD90.NEW & NOTEWORTHY We present a physiological basis for the interpretation of multielectrode array-derived, extracellular, electrical signals.
More Related Videos
10:41Laser-Induced Action Potential-Like Measurements of Cardiomyocytes on Microelectrode Arrays for Increased Predictivity of Safety Pharmacology
Published on: September 13, 2022
10:30Technical Applications of Microelectrode Array and Patch Clamp Recordings on Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes
Published on: August 4, 2022