Related Experiment Video
Updated: Jul 6, 2025

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Glomerular filtration rate measurement during platinum treatment for urothelial carcinoma: optimal methods for
Dag Rune Stormoen1,2, Ulla Nordström Joensen3,4, Gedske Daugaard5
1Department of Oncology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark. dag.rune.stormoen@regionh.dk.
Background:
We assessed the accuracy of four estimated glomerular filtration rate (eGFR) methods: MDRD, Cockcroft-Gault, CKD-EPI, and Wright.
Method:
The four methods were compared to measure GFR (mGFR) in patients with urothelial urinary tract cancer (T2-T4bNxMx) receiving platinum-based chemotherapy at Rigshospitalet, Copenhagen, from January 2019 to December 2021. Using standardized assays, creatinine values were measured, and mGFR was determined using Technetium-99 m diethylenetriaminepentaacetic acid (Tc-99 m-DTPA) or Cr-51-ethylenediaminetetraacetic acid (Cr-51-EDTA) plasma clearance. Patients (n = 146) with both mGFR and corresponding creatinine values available were included (n = 345 measurements).
Results:
The CKD-EPI method consistently demonstrated superior accuracy, with the lowest Total Deviation Index of 21.8% at baseline and 22.9% for all measurements compared to Wright (23.4% /24.1%), MDRD (26.2%/25.5%), and Cockcroft-Gault (25.x%/25.1%). Bland Altman Limits of agreement (LOA) ranged from - 32 ml/min (Cockcroft-Gault) to + 33 ml/min (MDRD), with CKD-EPI showing the narrowest LOA (- 27 ml/min to + 24 ml/min and lowest bias (0.3 ml/min). Establishing an eGFR threshold at 85 ml/min-considering both the lower limit of agreement (LOA) and the minimum cisplatin limit at 60 ml/min-allows for the safe omission of mGFR in 30% of patients in this cohort.
Conclusion:
CKD-EPI equation emerged as the most suitable for estimating kidney function in this patient group although not meeting benchmark criteria. We recommend its use for initial assessment and ongoing monitoring, and suggest mGFR for patients with a CKD-EPI estimated GFR below 85 ml/min. This approach could reduce costs and decrease laboratory time for 30% of our UC patients.
Related Concept Videos
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...