Design of fault location algorithm based on online distributed travelling wave for HV power cable
Chen Haohao1, Li Jing1,2, Chen Ping1
1School of Electrical and Electronic Engineering, Shandong University of Technology, Zibo, Shandong, China.
Abstract:
To tackle the challenge of localization failure due to traveling wave dispersion during a mid-line fault in a long high-voltage cable, this study conducts an in-depth analysis of the refraction characteristics of the cumulative three-phase sheath currents at cross commutation points and direct grounding points, facilitated by detailed theoretical derivation. We introduce the novel concept of a 'first traveling wave attenuation index,' which quantifies the peak of the initial faulted traveling wave. We strategically place distributed traveling wave detection devices solely in the first direct grounding box of each cross-interconnected main section, effectively segmenting the line into five distinct zones. These zones are identified based on the unique transient polarities exhibited by the first traveling wave of fault current at each impedance mismatch point along the cable. To overcome the issue of weak traveling wave signals collected at the first end measurement point, we propose an innovative peak detection method for the first wave. This method harnesses the power of empirical wavelet transform (EWT) and multi-resolution singular value decomposition (MRSVD), providing a significant boost in ranging accuracy compared to traditional wavelet methods. Simulation results validate the efficacy of our proposed fault location method, which accurately pinpoints the fault section by contrasting the polarity of the first wave peak of the sheath current detected at each measurement point. Notably, our method ensures safety and convenience as the equipment does not require direct contact with high voltage.
More Related Videos
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Related Concept Videos
Traveling Waves: Lossless Lines
Fault Types
For line-to-line faults occurring between phases B and C, the...
Power System Three-Phase Short Circuits
Cable Subjected to a Distributed Load
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Directional Relays