Related Experiment Video
Updated: Jul 22, 2026

Optimized System for Cerebral Perfusion Monitoring in the Rat Stroke Model of Intraluminal Middle Cerebral Artery Occlusion
Published on: February 17, 2013
CT-derived fractional flow reserve in intracranial arterial stenosis: A pilot study based on computational fluid
Zhuhao Yin1, Changsheng Zhou2, Jian Guo3
1Department of Radiology, Jinling Hospital, Nanjing Medical University, Nanjing, Jiangsu 210002, China.
Background:
CT-derived fractional flow reserve (CT-FFR) has been widely applied in coronary hemodynamic assessment. However, the feasieablity and standardization measurement in intracranial artery stenosis (ICAS) remains to be defined.
Purpose:
To demonstrate the feasibility of CT-FFR in ICAS functional assessment and explore the optimal CT-FFR measurement position with invasive FFR as reference standard.
Materials And Methods:
Nineteen patients (mean age, 58.6 years ± 1.9 [SD]; 13 men) with moderate to severe (≥50 %) ICAS undergoing guidewire-based pressure measurement and preoperative head CT angiography (CTA) were retrospectively enrolled. CT-FFR was measured in the following standard measurement positions, including the end of stenosis (D0), 1 cm distal to the stenosis (D1) and 2 cm distal to the stenosis (D2). Diagnostic performance of CT-FFR was assessed by the area under the curve (AUC) of receiver operating characteristic curves by assuming invasive FFR ≤ 0.80 or 0.75 as hemodynamically significant stenosis.
Results:
Excellent intra- and inter-observer agreement (ICC range, 0.930-0.992) was observed for CT-FFR measurement in different positions. Under different FFR thresholds, the diagnostic performance of CT-FFRD1 showed perfect prediction with AUC values of 1.000 (95 % CI: 0.824, 1.000). The sensitivity, specificity and AUC of CT-FFRD1 ≤ 0.80 in detecting FFR ≤ 0.80 was 0.94 (95 % CI: 0.68, 1.00), 1.00 (95 % CI: 0.31, 1.00) and 0.969 (95 % CI: 0.772, 1.000), respectively. Similar performance of CT-FFRD1 ≤ 0.75 was obtained for identifying FFR ≤ 0.75 with the AUC of 0.964. The strongest correlation (r = 0.915, p < 0.001) and agreement (mean difference: 0.02, 95 % limits of agreement: -0.16 to 0.19) were observed between CT-FFRD1 and FFR.
Conclusion:
Cerebral CT-derived fractional flow reserve (CT-FFR) measured 1 cm distal to stenosis achieved the most comparable results with invasive FFR, which indicated its potentially promising clinical application for evaluating the functional relevance of intracranial artery stenosis.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Related Concept Videos
Blood Flow
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Conservation of Mass in Finite Cotrol Volume
A system is defined as a collection of unchanging contents, and the conservation of mass states that a system's mass is constant.
Applications of Integration to Find Blood Flow