Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Research on improving the accuracy of laser-induced breakdown spectroscopy analysis by considering plasma attenuation
Chao Li1, Zhengjiang Ding2, Tao Zhang2
1School of Mechanical, Electrical & Information Engineering, Shandong University (Weihai), Weihai, Shandong, 264200, China.
Background:
Laser-induced breakdown spectroscopy (LIBS) is widely applied in various fields, but accuracy issues limit its further development. Signal uncertainty is the main reason that affects the accuracy of LIBS measurements, but the signal uncertainty caused by different plasmas exhibiting different radiation attenuation rates during the integration time is often neglected. There is a need for a method to correct LIBS signals by quantifying the radiation attenuation rate.
Results:
In order to reduce the uncertainty due to different plasma attenuation rates, the attenuation rates of the energy level radiation emitted by plasma are described as attenuation coefficients, which are obtained by linearly fitting the logarithm of the time series of line intensities. The calibration curve was corrected by attenuation coefficients for 4 major elements in 7 standard samples. The results showed that the line intensities corrected by attenuation coefficients showed better linearity with elemental concentrations.
Significance:
This study is important for improving the accuracy of LIBS measurements, and is also significant for modeling the plasma radiative attenuation of laser-induced plasma, and is expected to be applied to spectrometers that can obtain time series spectra of the same plasma to improve the accuracy of in-situ fast LIBS analysis.
More Related Videos
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
03:49Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Interference
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview