A proof of concept study on reliability assessment of different metal foil length based piezoelectric sensor for
Lukesh Parida1, Sumedha Moharana2, Romeu Vicente3
1Department of Civil Engineering, Shiv Nadar Institution of Eminence, Dadri, Uttar Pradesh, 201314, India.
Abstract:
Lead zirconate titanate (PZT) patches gained popularity in structural health monitoring (SHM) for its sensing and cost effective. However, a robust installation of PZT patches is challenging due to the often-complex geometry and non-accessibility of structural parts. For tubular structures, the curved surface can compromise the perfect bonding of PZT patches. To alleviate the above-mentioned challenges, the non-bonded and reusable configuration of sensor received considerable interest in the field of SHM. However, ensuring the repeatability and reproducibility of Electro-Mechanical Impedance (EMI) measurements is crucial to establish the reliability of these techniques. This work investigated the repeatability and reproducibility measures for one of non-bonded configuration of PZT patch i.e., Metal Foil Based Piezo Sensor (MFBPS). In addition, the concept, application, and suitability of MFBPS for impedance-based monitoring technique of Civil infrastructure are critically discussed. This study evaluates the effect of length of MFBPS on piezo coupled admittance signature. Also, this study evaluates repeatability and reproducibility of EMI measurements via statistical tools such as ANOVA and Gage R&R analysis. The statistical index CCDM was used to quantify the deviations of impedance signals. The overall result shows that the repeatability of the EMI measurements improves with a metal foil length of 500 mm. Overall, this investigation offers a useful point of reference for professionals and scholars to ensure the reliability of MFBPS for EMI techniques, a variant of piezoelectric sensor for SHM applications.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
10:39Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
Published on: August 5, 2020
Related Concept Videos
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Insulation Coordination
Electronic Distance Measuring Instruments