Related Experiment Video
Updated: Jul 1, 2026

Methods for Acute and Subacute Murine Hindlimb Ischemia
Published on: June 21, 2016
Inverted Ovation iX Limb to Treat an Isolated Common Iliac Artery Aneurysm
Said Ashkar1, Philippe Charbonneau2, Stephane Elkouri2,3
1Faculty of Medicine, University of Ottawa, Ontario, Canada.
Abstract:
In recent years, endovascular aneurysm repair has become the predominant method of managing abdominal aortic and common iliac artery aneurysms. Off-label use of different endovascular devices has allowed them to remain a viable option in many cases of atypical anatomy. Some studies have reported the use of iliac devices in an upside-down configuration when the common iliac artery aneurysm has a reverse-tapered morphology. However, the use of the Ovation iX (Endologix) limb in an upside-down configuration has not yet been reported. This limb offers a 14 mm distal end when inverted and offers good patency in the tortuous iliac morphology. This case report describes and illustrates the precise deployment of an inverted Ovation iX limb to treat an isolated common iliac artery aneurysm.
More Related Videos
07:04Creation of Two Saccular Elastase-Digested Aneurysms with Different Hemodynamics in One Rabbit
Published on: April 15, 2021
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...
Arteries of Lower Limbs
Aneurysm III: Interprofessional Care