Related Experiment Video
Updated: Jul 6, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Locked Wire Fixator for a Distal Radius Fracture With Malunion: A Case Report
Marika Nunotani1, Kiyohito Naito1,2, Nana Nagura1
1Department of Orthopaedics, Juntendo University, Tokyo, JPN.
Abstract:
Surgical treatment for a distal radius fracture using a volar locking plate is difficult if the distal radius malunion remains. Therefore, a different surgical method from volar locking plate fixation should be required. We report the case of an 83-year-old woman with a left dorsal displaced distal radius fracture. However, the deformity of the volar cortex of the radius was recognized because of a previous distal radius fracture. Therefore, osteosynthesis with a locked wire fixator was performed. At 12 months after surgery, the patient has returned to daily activities without difficulty. A locked wire fixator can be useful for treating a distal radius fracture with malunion of the volar cortex of the distal radius.