Related Experiment Videos
Development of a rapid extraction and high-performance liquid chromatographic separation for amitriptyline and six
Abstract:
The development of a rapid high-performance liquid chromatographic method for the determination of amitriptyline, amitriptyline-N-oxide, 10-hydroxyamitriptyline, 10-hydroxynortriptyline (E and Z isomers), nortriptyline and desmethylnortriptyline in plasma and liver tissue is described. A liquid--liquid extraction with hexane--butanol and back-extraction into phosphoric acid provides efficient extraction of amitriptyline-N-oxide along with amitriptyline and the other metabolites. A Supelcosil C8 reversed-phase column with 5-micron packing and a methanol--sodium phosphate buffer--amine modifier mobile phase was used. The combination of mobile phase pH and amine modifier concentration for the best separation within a reasonable analysis time for all seven solutes plus an internal standard was determined using a factorial design coupled with a multi-factor window diagram technique. Ultraviolet detection at 214 nm provided limits of detection of approximately 1 ng/ml.