Related Experiment Video
Updated: Jul 6, 2025

Laparoscopic-Assisted Seldinger Technique for Peritoneal Dialysis Catheter Insertion
Published on: May 23, 2025
The Association of Intra-Abdominal Adhesions with Peritoneal Dialysis Catheter-Related Complications
Mohammad Azfar Qureshi1, Serban Maierean2, John H Crabtree3
1Division of Nephrology, Department of Medicine, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada.
Background:
This study investigated the association of intra-abdominal adhesions with the risk of peritoneal dialysis (PD) catheter complications.
Methods:
Individuals undergoing laparoscopic PD catheter insertion were prospectively enrolled from eight centers in Canada and the United States. Patients were grouped based on the presence of adhesions observed during catheter insertion. The primary outcome was the composite of PD never starting, termination of PD, or the need for an invasive procedure caused by flow restriction or abdominal pain.
Results:
Seven hundred and fifty-eight individuals were enrolled, of whom 201 (27%) had adhesions during laparoscopic PD catheter insertion. The risk of the primary outcome occurred in 35 (17%) in the adhesion group compared with 58 (10%) in the no adhesion group (adjusted HR, 1.64; 95% confidence interval [CI], 1.05 to 2.55) within 6 months of insertion. Lower abdominal or pelvic adhesions had an adjusted HR of 1.80 (95% CI, 1.09 to 2.98) compared with the no adhesion group. Invasive procedures were required in 26 (13%) and 47 (8%) of the adhesion and no adhesion groups, respectively (unadjusted HR, 1.60: 95% CI, 1.04 to 2.47) within 6 months of insertion. The adjusted odds ratio for adhesions for women was 1.65 (95% CI, 1.12 to 2.41), for body mass index per 5 kg/m 2 was 1.16 (95% CI, 1.003 to 1.34), and for prior abdominal surgery was 8.34 (95% CI, 5.5 to 12.34). Common abnormalities found during invasive procedures included PD catheter tip migration, occlusion of the lumen with fibrin, omental wrapping, adherence to the bowel, and the development of new adhesions.
Conclusions:
People with intra-abdominal adhesions undergoing PD catheter insertion were at higher risk for abdominal pain or flow restriction preventing PD from starting, PD termination, or requiring an invasive procedure. However, most patients, with or without adhesions, did not experience complications, and most complications did not lead to the termination of PD therapy.
Related Concept Videos
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Appendicitis-I: Introduction
Etiology: Appendicitis can arise from various causes, primarily rooted in the obstruction of the appendix lumen. Factors contributing to this obstruction include fecal accumulation, lymphoid hyperplasia and, in...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Inflammatory Bowel Disease I: Ulcerative Colitis
Inflammatory bowel disease, or IBD, encompasses a group of disorders characterized by chronic inflammation or ulceration of the gastrointestinal tract.
Risk Factors
The exact cause of IBD remains unclear, although it is believed to be due to a mix of genetic, environmental, microbial, and immune factors. Genetic factors are significant in determining susceptibility to IBD, with family history being a critical risk factor. Individuals with a first-degree relative who has IBD are at...