Diagnosis of DC series arc fault based on multiple wavelet transform and optimal fractional wavelet energy entropy

Zhendong Yin1, Li Wang2, Xianqun Qiu1

  • 1College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou 225127, China.

PubMed

Related Concept Videos

Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
88
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
147
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
89
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
102
Discrete-Time Fourier Series01:20

Discrete-Time Fourier Series

The Discrete-Time Fourier Series (DTFS) is a fundamental concept in signal processing, serving as the discrete-time counterpart to the continuous-time Fourier series. It allows for the representation and analysis of discrete-time periodic signals in terms of their frequency components. Unlike its continuous counterpart, which utilizes integrals, the calculation of DTFS expansion coefficients involves summations due to the discrete nature of the signal.
For a discrete-time periodic signal x[n]...
272
Convergence of Fourier Series01:21

Convergence of Fourier Series

The Fourier series is a powerful mathematical tool for representing periodic signals as an infinite sum of complex exponentials. In practice, this infinite series is truncated to a finite number of terms, yielding a partial sum. This truncation makes the approximation of the signal feasible but introduces certain challenges, particularly near discontinuities, known as the Gibbs phenomenon.
The Gibbs phenomenon refers to the persistent oscillations and overshoots that occur near discontinuities...
148