Related Experiment Video
Updated: Jul 6, 2025

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Isatin-Schiff base functionalized graphene oxide as a highly selective turn-on fluorescent probe for the detection of
Hamed Barzinmehr1, Maryam Mirza-Aghayan2, Maryam Heidarian2
1Department of Chemistry and Biochemistry, Baylor University, One Bear Place, Waco, TX 76798-7348, USA; Chemistry and Chemical Engineering Research Center of Iran (CCERCI), P. O. BOX 14335-186, Tehran, Iran.
Abstract:
We investigated the use of isatin-Schiff base functionalized graphene oxide (ISBGO) as a selective fluorescent chemosensor for the detection of palladium ions. Selectivity tests indicated that over 23 metal ions tested, ISBGO (λex = 340 nm, λem = 504 nm) showed the highest affinity for Pd(II), displaying a 10.1-fold enhancement. Also, interference tests proved that in the presence of both Pd(II) and other metal ions, there was still high fluorescence intensity and no considerable quenching occurred. According to DFT and TD-DFT calculations, photo-induced electron transfer (PET) is responsible for the turn-on response produced by the chemosensor. Coordination of Pd(II) with ISBGO in fact blocks PET from imine nitrogen of 3-iminoindolin-2-one moiety to the benzene ring, which in turn leads to a turn-on response. In addition, Job's plot analysis and Benesi-Hildebrand approach suggest that ISBGO preferably forms a 1:1 complex with Pd(II) with an association constant of 1.020 × 105 M-1. Moreover, FT-IR spectroscopy and DFT study showed that amide oxygen and imine nitrogen of 3-iminoindolin-2-one moiety acted as binding sites of ISBGO. High sensitivity, fast response, great degree of sensitivity, short life time, low detection limit of 32 nM combined with high association constant (Kf) of 1.020 × 105 M-1 and increased fluorescence quantum yield (Φf) of roughly 1.5-fold in the presence of Pd (II), highlight the role of ISBGO as an excellent probe for sensing Pd(II) in aqueous solution.
More Related Videos
14:11Synthesis of pH Dependent Pyrazole, Imidazole, and Isoindolone Dipyrrinone Fluorophores using a Claisen-Schmidt Condensation Approach
Published on: June 10, 2021
10:38Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
Published on: March 3, 2010
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Photoluminescence: Applications