Related Experiment Video
Updated: Jul 5, 2025

Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Assessment of the Smartpill, a Wireless Sensor, as a Measurement Tool for Intra-Abdominal Pressure (IAP)
Andréa Soucasse1, Arthur Jourdan1, Lauriane Edin1
1IFSTTAR, Université Gustave Eiffel, Aix-Marseille Université, Laboratoire de Biomécanique Appliquée, Faculté de Médecine, Campus Nord, Boulevard Pierre Dramard, CEDEX 20, 13916 Marseille, France.
Abstract:
The SmartPill, a multisensor ingestible capsule, is marketed for intestinal motility disorders. It includes a pressure sensor, which could be used to study intra-abdominal pressure (IAP) variations. However, the validation data are lacking for this use. An experimental study was conducted on anesthetized pigs with stepwise variations of IAP (from 0 to 15 mmHg by 3 mmHg steps) generated by laparoscopic insufflation. A SmartPill, inserted by endoscopy, provided intragastric pressure data. These data were compensated to take into account the intrabdominal temperature. They were compared to the pressure recorded by intragastric (IG) and intraperitoneal (IP) wired sensors by statistical Spearman and Bland-Altmann analysis. More than 4500 pressure values for each sensor were generated on two animals. The IG pressure values obtained with the SmartPill were correlated with the IG pressure values obtained with the wired sensor (respectively, Spearman ρ coefficients 0.90 ± 0.08 and 0.72 ± 0.25; bias of -28 ± -0.3 mmHg and -29.2 ± 0.5 mmHg for pigs 1 and 2). The intragastric SmartPill values were also correlated with the IAP measured intra-peritoneally (respectively, Spearman ρ coefficients 0.49 ± 0.18 and 0.57 ± 0.30; bias of -29 ± 1 mmHg and -31 ± 0.7 mmHg for pigs 1 and 2). The SmartPill is a wireless and painless sensor that appears to correctly monitor IAP variations.
Related Concept Videos
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Assessment of the Abdomen III: Palpation
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.

