Related Experiment Video
Updated: Jul 1, 2026

Characterization of Thermal Transport in One-dimensional Solid Materials
Published on: January 26, 2014
Limitations of Bulk Diamond Sensors for Single-Cell Thermometry
Andrea Alessio1, Ettore Bernardi2, Ekaterina Moreva2
1Physics Department, University of Turin, Via P. Giuria 1, 10125 Turin, Italy.
Abstract:
The present paper reports on a Finite Element Method (FEM) analysis of the experimental situation corresponding to the measurement of the temperature variation in a single cell plated on bulk diamond by means of optical techniques. Starting from previous experimental results, we have determined-in a uniform power density approximation and under steady-state conditions-the total heat power that has to be dissipated by a single cell plated on a glassy substrate in order to induce the typical maximum temperature increase ΔTglass=1 K. While keeping all of the other parameters constant, the glassy substrate has been replaced by a diamond plate. The FEM analysis shows that, in this case, the maximum temperature increase is expected at the diamond/cell interface and is as small as ΔTdiam=4.6×10-4 K. We have also calculated the typical decay time in the transient scenario, which resulted in τ≈ 250 μs. By comparing these results with the state-of-the-art sensitivity values, we prove that the potential advantages of a longer coherence time, better spectral properties, and the use of special field alignments do not justify the use of diamond substrates in their bulk form.
More Related Videos
07:48An Externally-Heated Diamond Anvil Cell for Synthesis and Single-Crystal Elasticity Determination of Ice-VII at High Pressure-Temperature Conditions
Published on: June 18, 2020
05:49Mechano-Node-Pore Sensing: A Rapid, Label-Free Platform for Multi-Parameter Single-Cell Viscoelastic Measurements
Published on: December 2, 2022
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...