Objectives:
A flow-gradient classification is used to determine the indication for intervention for patients with severe aortic stenosis (AS) with discordant echocardiographic parameters. We investigated the agreement in flow-gradient classification by stroke volume (SV) measurement at the left ventricular outflow tract (LVOT) and at the left ventricle.
Methods:
Data were used from a prospective cohort study and patients with severe AS (aortic valve area index ≤0.6 cm2/m2) with preserved ejection fraction (>50%) were selected. SV was determined by an echocardiographic core laboratory at the LVOT and by subtracting the 2-dimensional left ventricle end-systolic from the end-diastolic volume (volumetric). Patients were stratified into 4 groups based on SV index (35 mL/m2) and mean gradient (40 mm Hg). The group composition was compared and the agreement between the SV measurements was investigated using regression, correlation, and limits of agreement. In addition, a systematic LVOT diameter overestimation of 1 mm was simulated to study flow-gradient reclassification.
Results:
Of 1118 patients, 699 were eligible. The group composition changed considerably as agreement on flow state occurred in only 50% of the measurements. LVOT SV was on average 15.1 mL (95% limits of agreement -24.9:55.1 mL) greater than volumetric SV. When a systematic 1-mm LVOT diameter overestimation was introduced, the low-flow groups halved.
Conclusions:
There was poor agreement in the flow-gradient classification of severe AS as a result of large differences between LVOT and volumetric SV. Furthermore, this classification was sensitive to small measurement errors. These results stress that parameters beyond the flow-gradient classification should be considered to ensure accurate recommendations for intervention.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
Related Concept Videos
Gradually Varying Flow
Pre-Procedural Guidelines for Assessing Blood Pressure
General Characteristics of Pipe Flow I
The classification of fluid...
Rapidly Varying Flow