Related Experiment Video
Updated: Aug 2, 2026

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
Half-Normal Saline vs Normal Saline for Cavotricuspid Isthmus-Dependent Atrial Flutter Ablation
Ana de Leon1, Matthew Hanson1, Nasser Alhammad1
1Division of Cardiology, Queen's University, Kingston, Ontario, Canada.
Background:
Cavotricuspid isthmus (CTI) ablation requires permanent bidirectional block to prevent recurrence of typical atrial flutter (AFL). Catheter irrigation with half-normal saline (HNS) produces larger and deeper lesions in experimental models compared with normal saline (NS). This study was performed to compare the clinical efficacy and safety of HNS vs NS irrigation for typical AFL ablation.
Methods:
Sixty patients undergoing catheter ablation of typical AFL were randomized 1:1 to NS or HNS irrigation. Endpoints included time to CTI block, acute reconnection, incidence of steam pops, and recurrence of AFL during follow-up.
Results:
Baseline characteristics were comparable between both arms. The mean age of the patients was 68.5 ± 8.2 years, 20% were female, and 32% had atrial fibrillation before being enrolled. Bidirectional CTI block was obtained in all patients with no difference in time to CTI block between groups (6.4 ± 4.4 minutes vs 7.6 ± 4.5 minutes, respectively; P = 0.15). There was a trend to less acute reconnection in the HNS group compared with NS (13.3% vs 26.6%; P = 0.46). Steam pops occurred in 4 patients using HNS vs none in the NS group, but no major complications were observed. During the follow-up, rate of AFL recurrence was similar between groups (6.7% with HNS vs 10% with NS; P = 0.5). There was no difference in time to recurrence (7.6 ± 6.9 vs 4.9 ± 4.5 months; P = 0.6).
Conclusions:
In this small pilot randomized controlled trial, there was no significant difference between HNS and NS for CTI ablation; however, HNS may increase the incidence of steam pops.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
Related Concept Videos
Anatomy of the Heart
Transcellular Transport of Solutes
Electrophysiology of Normal Cardiac Rhythm
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Disorder of Water Balance
Dehydration
Dehydration occurs when the body loses fluids (particularly water).
Causes:
The major causes of dehydration include excessive sweating, fever, vomiting, diarrhea, and diuresis.
Signs and Symptoms:
Symptoms primarily include intense...