Objectives:
Correct interpretation of thyroid function tests relies on correct reference intervals (RIs) for thyroid-stimulating hormone (TSH) and free thyroxine (FT4). ISO15189 mandates periodic verification of RIs, but laboratories struggle with cost-effective approaches. We investigated whether indirect methods (utilizing historical laboratory data) could replace the direct approach (utilizing healthy reference individuals) and compared results with manufacturer-provided RIs for TSH and FT4.
Methods:
We collected historical data (2008-2022) from 13 Dutch laboratories to re-establish RIs by employing indirect methods, TMC (for TSH) and refineR (for FT4). Laboratories used common automated platforms (Roche, Abbott, Beckman or Siemens). Indirect RIs (IRIs) were determined per laboratory per year and clustered per manufacturer (>1.000.000 data points per manufacturer). Direct RIs (DRIs) were established in 125 healthy individuals per platform.
Results:
TSH IRIs remained robust over the years for all manufacturers. FT4 IRIs proved robust for three manufacturers (Roche, Beckman and Siemens), but the IRI upper reference limit (URL) of Abbott showed a decrease of 2 pmol/L from 2015. Comparison of the IRIs and DRIs for TSH and FT4 showed close agreement using adequate age-stratification. Manufacturer-provided RIs, notably Abbott, Roche and Beckman exhibited inappropriate URLs (overall difference of 0.5-1.0 µIU/mL) for TSH. For FT4, the URLs provided by Roche, Abbott and Siemens were overestimated by 1.5-3.5 pmol/L.
Conclusions:
These results underscore the importance of RI verification as manufacturer-provided RIs are often incorrect and RIs may not be robust. Indirect methods offer cost-effective alternatives for laboratory-specific or platform-specific verification of RIs.
More Related Videos
04:14Author Spotlight: In Vivo Assessment of Thyroid Hormone Disruption Using the THAI Mouse Model
Published on: October 6, 2023
14:14Simultaneous Quantification of T-Cell Receptor Excision Circles TRECs and K-Deleting Recombination Excision Circles KRECs by Real-time PCR
Published on: December 6, 2014
Related Concept Videos
Synthesis and Regulation of Thyroid Hormones
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The...
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...