Related Experiment Video
Updated: Jul 5, 2025

Natural Product Discovery with LC-MS/MS Diagnostic Fragmentation Filtering: Application for Microcystin Analysis
Published on: May 31, 2019
Enhanced efficiency of MS/MS all-ion fragmentation for non-targeted analysis of trace contaminants in surface water
Maryam Vosough1,2, Amir Salemi3, Sarah Rockel3
1Instrumental Analytical Chemistry and Centre for Water and Environmental Research (ZWU), University of Duisburg-Essen, Universitätsstr. 5, Essen, 45141, Germany. maryam.vosough@uni-due.de.
Abstract:
Data-independent acquisition-all-ion fragmentation (DIA-AIF) mode of mass spectrometry can facilitate wide-scope non-target analysis of contaminants in surface water due to comprehensive spectral identification. However, because of the complexity of the resulting MS2 AIF spectra, identifying unknown pollutants remains a significant challenge, with a significant bottleneck in translating non-targeted chemical signatures into environmental impacts. The present study proposes to process fused MS1 and MS2 data sets obtained from LC-HRMS/MS measurements in non-targeted AIF workflows on surface water samples using multivariate curve resolution-alternating least squares (MCR-ALS). This enables straightforward assignment between precursor ions obtained from resolved MS1 spectra and their corresponding MS2 spectra. The method was evaluated for two sets of tap water and surface water contaminated with 14 target chemicals as a proof of concept. The data set of surface water samples consisting of 3506 MS1 and 2170 MS2 AIF mass spectral features was reduced to 81 components via a fused MS1-MS2 MCR model that describes at least 98.8% of the data. Each component summarizes the distinct chromatographic elution of components together with their corresponding MS1 and MS2 spectra. MS2 spectral similarity of more than 82% was obtained for most target chemicals. This highlights the potential of this method for unraveling the composition of MS/MS complex data in a water environment. Ultimately, the developed approach was applied to the retrospective non-target analysis of an independent set of surface water samples.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Analyzers: Overview
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometers
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences