Related Experiment Video
Updated: Jul 5, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Diagnostic accuracy of an artificial intelligence algorithm versus radiologists for fracture detection on cervical
Gaby J van den Wittenboer1,2, Brigitta Y M van der Kolk3,4,5, Ingrid M Nijholt3
1Department of Radiology and Nuclear Medicine, Isala, Dr. van Heesweg 2, Zwolle, The Netherlands. g.j.wittenboer@isala.nl.
Objectives:
To compare diagnostic accuracy of a deep learning artificial intelligence (AI) for cervical spine (C-spine) fracture detection on CT to attending radiologists and assess which undetected fractures were injuries in need of stabilising therapy (IST).
Methods:
This single-centre, retrospective diagnostic accuracy study included consecutive patients (age ≥18 years; 2007-2014) screened for C-spine fractures with CT. To validate ground truth, one radiologist and three neurosurgeons independently examined scans positive for fracture. Negative scans were followed up until 2022 through patient files and two radiologists reviewed negative scans that were flagged positive by AI. The neurosurgeons determined which fractures were ISTs. Diagnostic accuracy of AI and attending radiologists (index tests) were compared using McNemar.
Results:
Of the 2368 scans (median age, 48, interquartile range 30-65; 1441 men) analysed, 221 (9.3%) scans contained C-spine fractures with 133 IST. AI detected 158/221 scans with fractures (sensitivity 71.5%, 95% CI 65.5-77.4%) and 2118/2147 scans without fractures (specificity 98.6%, 95% CI 98.2-99.1). In comparison, attending radiologists detected 195/221 scans with fractures (sensitivity 88.2%, 95% CI 84.0-92.5%, p < 0.001) and 2130/2147 scans without fracture (specificity 99.2%, 95% CI 98.8-99.6, p = 0.07). Of the fractures undetected by AI 30/63 were ISTs versus 4/26 for radiologists. AI detected 22/26 fractures undetected by the radiologists, including 3/4 undetected ISTs.
Conclusion:
Compared to attending radiologists, the artificial intelligence has a lower sensitivity and a higher miss rate of fractures in need of stabilising therapy; however, it detected most fractures undetected by the radiologists, including fractures in need of stabilising therapy. Clinical relevance statement The artificial intelligence algorithm missed more cervical spine fractures on CT than attending radiologists, but detected 84.6% of fractures undetected by radiologists, including fractures in need of stabilising therapy.
Key Points:
The impact of artificial intelligence for cervical spine fracture detection on CT on fracture management is unknown. The algorithm detected less fractures than attending radiologists, but detected most fractures undetected by the radiologists including almost all in need of stabilising therapy. The artificial intelligence algorithm shows potential as a concurrent reader.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT