Related Experiment Video
Updated: Jul 5, 2025

Sampling and Pretreatment of Tooth Enamel Carbonate for Stable Carbon and Oxygen Isotope Analysis
Published on: August 15, 2018
Exploring δ13 C data compatibility in a broad δ13 C range: Reassembling δ13 C values obtained for NIST CO2 RMs
1Independent Researcher, Austria.
Rationale:
Stable isotope datasets obtained in different laboratories over years must be compared and combined. The strict compatibility in δ13 C at ±0.01‰ and ±0.02‰, k = 1, respectively, is required for observations of greenhouse gases CO2 and methane. That implies the long-term compatibility of calibrations realized at different laboratories. Thus far, this level of compatibility has not been demonstrated for pure CO2 in a broad δ13 C range and over years.
Methods:
We reassemble the δ13 C obtained in different laboratories for NIST CO2 RMs 8562-8564, which are pure CO2 gases. If the measurements are based on independent calibrations and reported on the same 17 O correction framework, δ13 C of all three RMs can be used to estimate the long-term δ13 C data compatibility.
Results:
δ13 C values obtained in different laboratories for NIST CO2 RMs 8562-8564 (a range of δ13 C from ~ -3.7‰ to ~ -41.6‰) from 1998 to 2020 agree within their uncertainties. Two NIST studies (1999 and 2004) have combined data from several laboratories using different Isotope ratio mass spectrometry (IRMS) methods and somewhat different approaches. Three single-laboratory studies (2003, 2008, and 2020) have used the same type of IRMS and similar approaches. The δ13 C values from these laboratories agree within ±0.01‰, k = 1, over the entire δ13 C range and have uncertainties about two times lower than those obtained at NIST by combining data from several laboratories.
Conclusion:
The δ13 C values for NIST CO2 RMs 8562-8564 obtained in three laboratories using the same IRMS (2003, 2008, and 2020) agree within ±0.01‰, k = 1. First, this confirms the long-term stability in δ13 C of RMs 8562-8564. Second, this example of compatibility in δ13 C calibrations on pure CO2 , from -3.7‰ to -41.6‰, is relevant to stable isotope measurements of greenhouse gases CO2 and methane. Third, this confirms the high accuracy of the δ13 C(air-CO2 ) calibrations performed in 2003 and 2008 for the project Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrumented Container (CARIBIC).
More Related Videos
10:16Design and Operation of a Continuous 13C and 15N Labeling Chamber for Uniform or Differential, Metabolic and Structural, Plant Isotope Labeling
Published on: January 16, 2014
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Carbon-13 (¹³C) NMR: Overview
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Mass Spectrometry: Isotope Effect
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
High-Resolution Mass Spectrometry (HRMS)
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR