Comparison of Free-Breathing 3D Phase-Resolved Functional Lung (PREFUL) MRI With Dynamic 19F Ventilation MRI in
Filip Klimeš1,2, Arnd J Obert3, Julienne Scheller1,2
1Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hanover, Germany.
Background:
Non-contrast-enhanced 1H magnetic resonance imaging (MRI) with full lung coverage shows promise for assessment of regional lung ventilation but a comparison with direct ventilation measurement using 19F MRI is lacking.
Purpose:
To compare ventilation parameters calculated using 3D phase-resolved functional lung (PREFUL) MRI with 19F MRI.
Study Type:
Prospective.
Population:
Fifteen patients with asthma, 14 patients with chronic obstructive lung disease, and 13 healthy volunteers.
Field Strength/Sequence:
A 3D gradient-echo pulse sequence with golden-angle increment and stack-of-stars encoding at 1.5 T.
Assessment:
All participants underwent 3D PREFUL MRI and 19F MRI. For 3D PREFUL, static regional ventilation (RVent) and dynamic flow-volume cross-correlation metric (FVL-CM) were calculated. For both parameters, ventilation defect percentage (VDP) values and ventilation defect (VD) maps (including a combination of both parameters [VDPCombined]) were determined. For 19F MRI, images from eight consecutive breaths under volume-controlled inhalation of perfluoropropane were acquired. Time-to-fill (TTF) and wash-in (WI) parameters were extracted. For all 19F parameters, a VD map was generated and the corresponding VDP values were calculated.
Statistical Tests:
For all parameters, the relationship between the two techniques was assessed using a Spearman correlation (r). Differences between VDP values were compared using Bland-Altman analysis. For regional comparison of VD maps, spatial overlap and Sørensen-Dice coefficients were computed.
Results:
3D PREFUL VDP values were significantly correlated to VDP measures by 19F (r range: 0.59-0.70). For VDPRVent, no significant bias was observed with VDP of the third and fourth breath (bias range = -6.8:7.7%, P range = 0.25:0.30). For VDPFVL-CM, no significant bias was found with VDP values of fourth-eighth breaths (bias range = -2.0:12.5%, P range = 0.12:0.75). The overall spatial overlap of all VD maps increased with each breath, ranging from 61% to 81%, stabilizing at the fourth breath.
Data Conclusion:
3D PREFUL MRI parameters showed moderate to strong correlation with 19F MRI. Depending on the 3D PREFUL VD map, the best regional agreement was found to 19F VD maps of third-fifth breath.
Level Of Evidence:
3 TECHNICAL EFFICACY: Stage 2.
More Related Videos
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Magnetic Resonance Imaging
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...