Accuracy of Noninvasive Blood Pressure Monitoring in Critically Ill Adults
Erin N Haber1, Rajiv Sonti1, Suzanne M Simkovich1
1Division of Pulmonary, Critical Care and Sleep Medicine, MedStar Georgetown University Hospital, Washington DC, USA.
Abstract:
Background: Blood pressure (BP) is routinely invasively monitored by an arterial catheter in the intensive care unit (ICU). However, the available data comparing the accuracy of noninvasive methods to arterial catheters for measuring BP in the ICU are limited by small numbers and diverse methodologies. Purpose: To determine agreement between invasive arterial blood pressure monitoring (IABP) and noninvasive blood pressure (NIBP) in critically ill patients. Methods: This was a single center, observational study of critical ill adults in a tertiary care facility evaluating agreement (≤10% difference) between simultaneously measured IABP and NIBP. We measured clinical features at time of BP measurement inclusive of patient demographics, laboratory data, severity of illness, specific interventions (mechanical ventilation and dialysis), and vasopressor dose to identify particular clinical scenarios in which measurement agreement is more or less likely. Results: Of the 1852 critically ill adults with simultaneous IABP and NIBP readings, there was a median difference of 6 mm Hg in mean arterial pressure (MAP), interquartile range (1-12), P < .01. A logistic regression analysis identified 5 independent predictors of measurement discrepancy: increasing doses of norepinephrine (adjusted odds ratio [aOR] 1.10 [95% confidence interval, CI 1.08-1.12] P = .03 for every change in 5 µg/min), lower MAP value (aOR 0.98 [0.98-0.99] P < .01 for every change in 1 mm Hg), higher body mass index (aOR 1.04 [1.01-1.09] P = .01 for an increase in 1), increased patient age (aOR 1.31 [1.30-1.37] P < .01 for every 10 years), and radial arterial line location (aOR 1.74 [1.16-2.47] P = .04). Conclusions: There was broad agreement between IABP and NIBP in critically ill patients over a range of BPs and severity of illness. Several variables are associated with measurement discrepancy; however, their predictive capacity is modest. This may guide future study into which patients may specifically benefit from an arterial catheter.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure