Related Experiment Video
Updated: Jul 5, 2025

Manufacture of a Multi-Purpose Low-Cost Animal Bench-Model for Teaching Tracheostomy
Published on: May 18, 2019
Supraglottic Airway Devices: Present State and Outlook for 2050
André A J van Zundert1, Stephen P Gatt2,3, Tom C R V van Zundert4
1From the Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, & The University of Queensland, Brisbane, Queensland, Australia.
None:
Correct placement of supraglottic airway devices (SGDs) is crucial for patient safety and of prime concern of anesthesiologists who want to provide effective and efficient airway management to their patients undergoing surgery or procedures requiring anesthesia care. In the majority of cases, blind insertion of SGDs results in less-than-optimal anatomical and functional positioning of the airway devices. Malpositioning can cause clinical malfunction and result in interference with gas exchange, loss-of-airway, gastric inflation, and aspiration of gastric contents. A close match is needed between the shape and profile of SGDs and the laryngeal inlet. An adequate first seal (with the respiratory tract) and a good fit at the second seal of the distal cuff and the gastrointestinal tract are most desirable. Vision-guided insertion techniques are ideal and should be the way forward. This article recommends the use of third-generation vision-incorporated-video SGDs, which allow for direct visualization of the insertion process, corrective maneuvers, and, when necessary, insertion of a nasogastric tube (NGT) and/or endotracheal tube (ETT) intubation. A videoscope embedded within the SGD allows a visual check of the glottis opening and position of the epiglottis. This design affords the benefit of confirming and/or correcting a SGD's position in the midline and rotation in the sagittal plane. The first clinically available video laryngeal mask airways (VLMAs) and multiple prototypes are being tested and used in anesthesia. Existing VLMAs are still not perfect, and further improvements are recommended. Additional modifications in multicamera technology, to obtain a panoramic view of the SGD sitting correctly in the hypopharynx and to prove that correct sizes have been used, are in the process of production. Ultimately, any device inserted orally-SGD, ETT, NGT, temperature probe, transesophageal scope, neural integrity monitor (NIM) tubes-could benefit from correct vision-guided positioning. VLMAs also allow for automatic recording, which can be documented in clinical records of patients, and could be valuable during teaching and research, with potential value in case of legal defence (with an airway incident). If difficulties occur with the airway, documentation in the patient's file may help future anesthesiologists to better understand the real-time problems. Both manufacturers and designers of SGDs may learn from optimally positioned SGDs to improve the design of these airway devices.
More Related Videos
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Suctioning the Nasopharyngeal Airway
Equipment Required
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...