Related Experiment Video
Updated: Jun 6, 2026

Voltage Biasing, Cyclic Voltammetry, & Electrical Impedance Spectroscopy for Neural Interfaces
Published on: February 24, 2012
An electrode-impedance-aware neurostimulator IC that achieves low-power consumption and fast charge balance
Yawen Shi1, Quanbei Chang1, Xiao Liu2
1School of Information Science and Technology, Fudan University, Shanghai 200433, China; State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai 201203, China.
Abstract:
Implantable neural stimulation is becoming increasingly popular for treating neurologically impaired patients, restoring neural functions which would otherwise be lost due to diseases or injuries. The charge balance of the stimulus pulses is of paramount importance for the long-term safety of the electrode-tissue interface. This paper presents a novel neurostimulator integrated circuit in which two novel charge balancing schemes are proposed. One is based on acquiring the access resistance part (RS) of the inter-electrode impedance. Thanks to its adaptive anodic phase, the RS-based charge balance circuit does not require an additional discharge phase, achieving faster charge balance than most existing stimulator ICs. The other scheme is based on acquiring the double-layer capacitance part (CDL) of the inter-electrode impedance and the entire charge balancing process (inc. monitoring, computation and compensation) is performed in the analog domain. This is in sharp contrast to the existing electrode-impedance-aware charge balancing schemes which require ADCs and compute the net charge in the digital domain. Hence the new impedance-aware charge-balancing scheme is faster and more power friendly. The impedance-aware stimulator ASIC has been implemented using X-FAB's 180-nm CMOS process. The post-layout simulation results suggest a good charge balance is achieved as the voltage deviation from the electrode offset voltage on the electrode after the charge compensation reduces to 2.64 mV and -1.39 mV under the RS-based and CDL-based charge balancing schemes, respectively. The additional power overhead due to the proposed CDL-based charge balancer circuit is 2.46 μW at a stimulation rate of 400 Hz.
More Related Videos
08:17Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
Published on: September 27, 2018
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
Related Concept Videos
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
Types of Reversible Electrodes