Introduction:
A bio-implant is a drug-delivery system that is implanted in the human body for a period of more than 30 days. Electromechanical systems are one type of bio-implant that has recently been introduced as a new generation of targeted drug delivery methods. The overarching goal of utilizing these systems is to integrate electrical and mechanical features in order to benefit from the numerous applications of these two systems when used together. The current study aimed to design a prototype of an electromechanical system using Fused Deposition Modeling (FDM), Selective Laser Sintering (SLS), and MultiJet Fusion (MJF) techniques for drug delivery that can release a specific drug dosage in the patient's body by connecting to a sensor or under the control of a signal sent by the physician.
Methods:
Initially, the implant chambers were created in the form of a hollow cylinder, closed at one end, using three different types of 3D printers: FDM, SLS, and MJF. Each implant was then filled with a model drug (pentoxifylline) and sealed with a thin gold membrane. To achieve the lowest voltage required to melt the gold membrane, an electric circuit with controllable DC voltage generator was designed. Finally, the mechanical resistance, drug release rate, and surface morphology of the designed implants were evaluated.
Results:
The MJF 3D printer, overally, had higher printing precision and repeatability than other printers; however, the implants printed by the FDM 3D printer were more accurate than other techniques (P value < 0.001), similar to the dimensions of the designed file. The mechanical resistance of the implants was also evaluated, and the polylactic acid implants printed by FDM had the highest value of Young's modulus in both the standard samples and the designed implants. During the 3-month drug leakage study, FDM 3D printed implant had a greater ability to store the desired drug load (P value < 0.001), Furthermore, the SEM micrographs revealed that the polylactic acid implants printed by FDM had minimal porosity in their structure and the layers were well adhered together. The gold membrane with a middle diameter of 2 mm required the lowest voltage of 6 V. As a result, the final electrical circuit was designed with smaller dimensions in order to achieve the voltage required to melt the gold membrane.
Conclusion:
Due to the lack of drug leakage and other mechanical studies, the electromechanical implant produced by the FDM 3D printer was chosen as the optimal electromechanical implant in this study. Along with the designed small circuit, this implant can release a drug dosage in the patient's body at the physician's demand.
More Related Videos
08:17An Additive Manufacturing Technique for the Facile and Rapid Fabrication of Hydrogel-based Micromachines with Magnetically Responsive Components
Published on: July 18, 2018
08:17Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
Published on: September 27, 2018
Related Concept Videos
Modified-Release Drug Delivery Systems: Rate-Programmed II
Drug Delivery Systems: Different Types
Modified-Release Drug Delivery Systems: Overview
Modified-Release Drug Delivery Systems: Classification
Modified-Release Drug Delivery Systems: Rate-Programmed I
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices