Related Experiment Video
Updated: Jul 5, 2025

High-throughput, Automated Extraction of DNA and RNA from Clinical Samples using TruTip Technology on Common Liquid Handling Robots
Published on: June 11, 2013
Numerical and experimental investigation on the performance of rapid ultrasonic-assisted nucleic acid extraction
Dongxu Zhang1, Yang Hu2, Runxin Gao3
1National Institute of Diagnostics and Vaccine Development in Infectious Diseases,State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics,National Innovation Platform for Industry-Education Integration in Vaccine Research,the Research Unit of Frontier Technology of Structural Vaccinology of Chinese Academy of Medical Sciences,Xiamen University, Xiamen, Fujian, China.
Background:
Nucleic acid extraction (NAE) is an essential step in the whole process of nucleic acid detection (NAT). Traditional manual extraction methods are time-consuming and laborious, unfavorable to the point-of-care testing of nucleic acids. Ultrasound has been emphasized due to its noncontact and easy-to-manipulate characteristics, and integration with microfluidic chip can realize rapid NAE through acoustic streaming effect. The uniformity of magnetic bead mixing in this process is a critical factor affecting the extraction effect. In this study, we developed an ultrasound-assisted NAE technique based on the magnetic bead method and optimized the chip structure to achieve rapid NAE.
Result:
We use ultrasonic-assisted coupled with magnetic bead method for ultra-fast NAE. The mixing process of magnetic beads driven by acoustic streaming is simulated by a dispersive two-phase flow model, and the ultrasonic incidence angle (θin), cone structure aspect ratio (Dc/Hc) and sheet structure thickness (Hp) are optimized to enhance the mixing performance. Furthermore, the effectiveness of NAE is validated by utilizing quantitative real-time PCR (qPCR) detection. The findings reveal that a θin value of 10° yields superior mixing performance compared to other incidence angles, resulting in a maximum increase of 84 % in mixing intensity. When Dc/Hc = 0.5 and Hp = 0.5 mm, the maximum mixing index in the localized region of the chamber after 1 s of ultrasound action can reach 83.6 % and 92.5 %, respectively. Compared to the original chamber, the CT values extracted after 5 s of ultrasound action shifted forward by up to 1.9 ct and 4.1 ct, respectively.
Significance:
The dispersed two-phase flow model can effectively simulate the mixing process of magnetic beads, which plays an important role in assisting the structural design of chip extraction chambers. The single-step mixing of ultrasound-assisted NAE takes only 15s to achieve an extraction performance comparable to manual extraction. The extraction process can be completed within 7 min after integrating this technology with microfluidic chips and automated equipment, providing a solution for automated and efficient NAE.