Related Experiment Video
Updated: Jul 5, 2025

A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Arterial and venous peripheral vascular assessment using wearable electro-resistive morphic sensors
Elham Shabani Varaki1, Gaetano D Gargiulo1,2, Matthew Malone3,4
1The MARCS Institute for Brain, Behaviour and Development, Western Sydney University, Sydney, Australia.
Abstract:
Peripheral vascular diseases (PVDs) represent a significant burden on global human health and healthcare systems. With continued growth in obesity and diabetes, it is likely that the incidence of these conditions will increase. As many PVDs remain undiagnosed, low-cost and easy to use diagnostic methods are required. This work uses newly developed wearable electro-resistive morphic sensors to assess venous and arterial competence in the lower limbs of 36 healthy subjects. Comparison of this HeMo device was made to currently available benchtop light reflection rheography and photoplethymography devices. Results indicate that HeMo can detect the physiological signals of interest for both chronic venous insufficiency and peripheral arterial disease and all subjects were interpreted as healthy by each system. However, measurement repeatability of HeMo was highlighted as an issue that requires further system development. Furthermore, as HeMo captures changes in a section of limb circumference due to changes in underlying blood movement, rather than at a single point, the recorded signal is typically damped by comparison. This factor should be considered in any future developments.
More Related Videos
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

