The Laboratory Characterization of Fugitive Aerosol Emissions From a Standard Jet Nebulizer With and Without a
Manhar Dhanak1, Siddhartha Verma1, Patrick G Hughes2
1Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, USA.
Abstract:
Background and objective The risk of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) transmission from patients with coronavirus disease 2019 (COVID-19) during nebulization is unclear. In this study, we aimed to address this issue. Methods Fugitive emissions of aerosolized saline during nebulization were observed using a standard jet nebulizer fitted with unfiltered and filtered mouthpieces connected via a mannequin to a breathing simulator. Fugitive emissions were observed by using a laser sheet and captured on high-definition video, and they were measured by using optical particle counters positioned where a potential caregiver may be administering nebulization and three other locations in the sagittal plane at various distances downstream of the mannequin. Results The use of a standard unfiltered mouthpiece resulted in significant emission of fugitive aerosols ahead of and above the mannequin (spread over 2 m in front). A mouthpiece with a filter-adaptor effectively suppressed the emissions, with only minor leakage from the nebulizer cup. Particle count measurements supported the visual observations, providing total particle count levels and aerosol concentration levels at the measurement locations. The levels decayed slowly with downstream distance. Conclusions The visualization described above captured the dispersion of emitted aerosols in the plane of the laser sheet, aligned with the sagittal plane. The particle count measurements provided temporal and spatial distributions of the aerosol concentration levels over the time and locations considered. However, the exhaled air and aerosolized droplets spread three-dimensionally in front of and above the mannequin. The results visually highlight the effectiveness of using a filtered mouthpiece in suppressing the fugitive aerosols and identify an approach for limiting the occupational exposure of healthcare workers to these emissions while administering nebulized therapies.
More Related Videos
05:07Development of a Nose-only Inhalation Toxicity Test Chamber That Provides Four Exposure Concentrations of Nano-sized Particles
Published on: March 18, 2019
08:33Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
Published on: April 12, 2022