Related Experiment Video
Updated: Jul 5, 2025

Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
Published on: December 14, 2020
A Comparison of Functional Luminal Imaging Probe With High-resolution Manometry, Timed Barium Esophagram, and pH
James D Miller1, Brendan P Kemple1,2, Joni K Evans3
1Wake Forest University School of Medicine.
Objective:
The aims of this study are to determine the functional luminal imaging probe's (FLIP) diagnostic utility by comparing FLIP measurements with results from other esophageal evaluation standards.
Background:
The FLIP is an esophageal evaluation technique performed at the time of endoscopy. Few studies have evaluated FLIP diagnostic capabilities compared with the established testing techniques, including high-resolution manometry (HRIM), time barium esophagram (TBE), and 24-hour impedance-pH monitoring.
Patients And Methods:
A retrospective review was performed for 413 preintervention patients who underwent FLIP testing during endoscopy. Data from HRIM, 24-hour pH monitoring, and TBE were compared.
Results:
Abnormal Distensibility Index (DI) was associated with abnormal integrated relaxation pressure (IRP; P = 0.003). Average DI was higher in patients with abnormal IRP (>15 mm Hg) when a hiatal hernia was present ( P = 0.025). The total agreement between correlated diagnoses from FLIP and HRIM was 33.5%. DI was not associated with acid exposure time on pH monitoring. Agreement between FLIP and TBE was 49% with a sensitivity of 98.1% and a specificity of 36.5%. A 60 mL distension had a significantly lower detection rate than 40 mL and 50 mL for active peristalsis and was unaffected by pressure ( P < 0.05).
Conclusions:
FLIP as an adjunct to HRIM is supported by strong metric correlation. FLIP was not correlated to pH monitoring findings, suggesting FLIP is not useful in reflux assessment. The agreement between FLIP and TBE was lower than in previous studies. Hiatal hernia impacted the normality between DI and IRP, not between FLIP and TBE. We suggest analyzing peristaltic patterns on panometry at all fill volumes to optimize detection.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...