Related Experiment Video
Updated: Jul 5, 2025

Fabrication and Testing of Photonic Thermometers
Published on: October 24, 2018
Temperature Sensitivity Control of an Inkjet-Printed Optical Resonator on Pillar
Marc-Antoine Bianki1, Régis Guertin1, Cédric Lemieux-Leduc1
1Department of Engineering Physics, Polytechnique Montréal, Montréal, Quebec H3T 1J4, Canada.
Abstract:
We report a whispering gallery mode resonator on a pillar using inkjet printing combined with traditional microfabrication techniques. This approach enables several different polymers on the same chip for sensing applications. However, polymers inherently exhibit sensitivity to multiple stimuli. To mitigate temperature sensitivity, careful selection of design parameters is crucial. By precisely tuning the undercut-to-radius ratio of the resonator, a linear dependence in temperature sensitivity ranging from -41.5 pm/°C to 23.4 pm/°C, with a zero-crossing point at 47.6% is achieved. Consequently, it is feasible to fabricate sensing devices based on undercut microdroplets with minimal temperature sensitivity. The lowest measured temperature sensitivity obtained was 5.9 pm/°C, for a resonator with an undercut-to-radius ratio of 53%.