Normative High-Resolution Pharyngeal Manometry: Impact of Age, Size of System, and Sex on Primary Metrics and
Corinne A Jones1,2,3, Jilliane F Lagus1, Suzan M Abdelhalim3
1Department of Speech, Language, and Hearing Sciences, Moody College of Communication, The University of Texas at Austin, Austin, TX, USA.
Abstract:
There have been many reports of normative pharyngeal swallowing pressures using high-resolution pharyngeal manometry, but there is a fair amount of between-subject variance in reported pressure parameters. The purpose of this study was to put forward normative pharyngeal high-resolution manometry measures across the lifespan and investigate the effects of age, size of system, and sex. High-resolution pharyngeal manometry was performed on 98 healthy adults (43 males) between the ages 21 and 89. Pressure duration, maxima, integral, and within-individual variability metrics were averaged over 10 swallows of 10-ml thin liquid. Multiple linear and logistic regressions with model fitting were used to examine how pharyngeal pressures relate to age, pharyngeal size, and sex. Age was associated with tongue base maximum pressure, tongue base maximum variability, and upper esophageal sphincter-integrated relaxation pressure (F3,92 = 6.69; p < 0.001; adjusted R2 = 0.15). Pharyngeal area during bolus hold was associated with velopharynx integral (F1,89 = 5.362; p = 0.02; adjusted R2 = 0.05), and there was no significant model relating pharyngeal pressures to C2-C4 length (p < 0.05). Sex differences were best described by tongue base integral and hypopharynx maximum variability (χ2 = 10.27; p = 0.006; pseudo R2 = 0.14). Normative data reveal the distribution of swallow pressure metrics which need to be accounted for when addressing dysphagia patients, the importance of pressure interactions in normal swallow, and address the relative stability of swallow metrics with normal aging.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...