Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

High-throughput screening of amorphous solid dispersions: a systematic approach to enhance bioaccessibility of a poorly soluble drug.

European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences·2025
Same author

Biowaiver monograph for immediate-release solid oral dosage forms: Amlodipine besylate.

Journal of pharmaceutical sciences·2025
Same author

Biowaiver monograph for immediate-release solid oral dosage forms: Empagliflozin.

Journal of pharmaceutical sciences·2025
Same author

Canine Mdr1 Knockout MDCK Cells Reliably Estimate Human Small Intestinal Permeability (<i>P</i><sub>eff</sub>) and Fraction Absorbed (<i>f</i><sub>a</sub>).

Molecular pharmaceutics·2025
Same author

Corrigendum to "Characteristics of contents in the upper gastrointestinal lumen after a standard high-calorie high-fat meal and implications for the in vitro drug product performance testing conditions" [Eur J Pharm Sci. 155 (2020) 105535].

European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences·2025
Same author

Combining high-throughput ASD screening with the rDCS to streamline development of poorly soluble drugs.

European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences·2025

Related Experiment Video

Updated: Jul 5, 2025

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.1K

Silicon-Based Piezo Micropumps Enable Fully Flexible Drug Delivery Patterns.

David Plano1, Sebastian Kibler2, Niklas Rudolph1

  • 1Fraunhofer Institute for Translational Medicines and Pharmacology ITMP, Theodor-Stern-Kai 7, 60596 Frankfurt am Main, Germany.

Journal of Pharmaceutical Sciences
|January 17, 2024
PubMed
Summary

A new piezoelectric micropump enables precise and reproducible drug delivery. This innovative device offers flexible control over drug release profiles, paving the way for personalized medicine applications.

Keywords:
Acetaminophen (paracetamol)FingolimodMetoprololMicropumpProgrammable drug deliveryRelease profile

More Related Videos

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
10:22

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices

Published on: September 2, 2009

13.8K
A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

13.8K

Related Experiment Videos

Last Updated: Jul 5, 2025

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.1K
High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
10:22

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices

Published on: September 2, 2009

13.8K
A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

13.8K

Area of Science:

  • Biomedical Engineering
  • Materials Science
  • Pharmaceutical Sciences

Background:

  • Drug release precision is limited by current formulation methods.
  • Advanced drug delivery systems are needed for targeted therapy and optimal drug efficacy.
  • Existing approaches struggle with reproducibility due to excipient and API properties.

Purpose of the Study:

  • To evaluate a piezoelectric micropump for precise drug delivery.
  • To assess the pump's performance with both API solutions and suspensions.
  • To explore the potential for customized and programmable drug release profiles.

Main Methods:

  • Utilized a 5 × 5 × 0.6 mm³ piezoelectric micropump for drug delivery experiments.
  • Tested the micropump with solutions of highly soluble active pharmaceutical ingredients (APIs).
  • Investigated the delivery of suspensions with varying particle sizes and concentrations.

Main Results:

  • The micropump demonstrated high precision and reproducibility when delivering API solutions.
  • Pumping performance for suspensions was significantly influenced by particle size and concentration.
  • Flexible programming of release profiles was achieved with API solutions.

Conclusions:

  • The piezoelectric micropump provides a foundation for advanced drug delivery systems.
  • This technology enables customized and programmable drug release, advancing personalized medicine.