Enantioseparation of agrochemicals by gas chromatography. Exploring columns based on cyclodextrin derivatives
Emilia Frickel Critto1, Sol Giovannoni1, Carlina Lancioni1
1Laboratorio de Investigación y Desarrollo de Métodos Analíticos (LIDMA), División Química Analítica, Facultad de Ciencias Exactas, UNLP, CIC-PBA, La Plata, Argentina.
Abstract:
The main goal of this work is to expand the availability of chiral columns for the analysis of agrochemicals by gas chromatography. A broader offer of chiral stationary phases would allow shifting toward enantioselective analytical techniques environmentally more friendly for those compounds. We prepared seven chiral capillary columns based on derivatives of either, β-cyclodextrin or γ-cyclodextrins dissolved at high concentrations, in two typical polysiloxanes with different polarities, demonstrating not only the significance of the chiral selector but also of the polymer solvent for achieving adequate enantioseparation of some agrochemicals. The enantiorecognition ability of each column was evaluated with 20 volatile and semivolatile agrochemicals, possessing one or two chiral centers. Besides, to elute more polar agrochemicals, as well as to enhance enantioselectivity, three derivatization procedures targeting the carboxyl and/or amine group were evaluated. The results revealed that the prepared column consisting of octakis(2,3-di-O-acetyl-6-O-tertbutyldimethylsilyl)-γ-cyclodextrin dissolved in (14%-cyanopropyl-phenyl)-86%-methyl-polysiloxane provides the broadest enantiorecognition capacity. This column allowed the enantioseparation of seventeen chiral agrochemicals, including metalaxyl, furalaxyl, and four imidazolinones, which were not enantioseparated in the remaining columns. To the best of our knowledge, glufosinate, fluorochloridone, fenarimol, furalaxyl, and four imidazolinones were enantioseparated by gas chromatography for the first time.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Principles Of Column Chromatography
