Related Experiment Video
Updated: Jul 5, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Deep Learning for Automated Measurement of Total Cardiac Volume for Heart Transplantation Size Matching
Nicholas A Szugye1, Neeraja Mahalingam2, Elanchezhian Somasundaram2
1Cleveland Clinic Foundation.
Background:
Total Cardiac Volume (TCV) based size matching using Computed Tomography (CT) is a novel technique to compare donor and recipient heart size in pediatric heart transplant that may increase overall utilization of available grafts. TCV requires manual segmentation, which limits its widespread use due to time and specialized software and training needed for segmentation.
Objective:
This study aims to determine the accuracy of a Deep Learning (DL) approach using 3-dimensional Convolutional Neural Networks (3D-CNN) to calculate TCV, with the clinical aim of enabling fast and accurate TCV use at all transplant centers.
Materials And Methods:
Ground truth TCV was segmented on CT scans of subjects aged 0-30 years, identified retrospectively. Ground truth segmentation masks were used to train and test a custom 3D-CNN model consisting of a Dense-Net architecture in combination with residual blocks of ResNet architecture.
Results:
The model was trained on a cohort of 270 subjects and a validation cohort of 44 subjects (36 normal, 8 heart disease retained for model testing). The average Dice similarity coefficient of the validation cohort was 0.94 ± 0.03 (range 0.84-0.97). The mean absolute percent error of TCV estimation was 5.5%. There is no significant association between model accuracy and subject age, weight, or height. DL-TCV was on average more accurate for normal hearts than those listed for transplant (mean absolute percent error 4.5 ± 3.9 vs. 10.5 ± 8.5, p = 0.08).
Conclusion:
A deep learning based 3D-CNN model can provide accurate automatic measurement of TCV from CT images.