Related Experiment Video
Updated: Jul 5, 2025

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Introducing a novel respiratory function monitor for neonatal resuscitation training
A M Dalley1,2, K A Hodgson1,2,3, J A Dawson1,2,4
1Newborn Research Centre, The Royal Women's Hospital, Level 7, 20 Flemington Road, Parkville, Victoria 3052, Australia.
Background:
A respiratory function monitor (RFM) gives immediate feedback, allowing clinicians to adjust face mask ventilation to correct leak or inappropriate tidal volumes. We audited the satisfaction of clinicians with a neonatal resuscitation training package, incorporating a novel RFM.
Methods:
This was a mixed-methods study conducted at The Royal Women's Hospital, Melbourne, Australia. Clinicians were approached to complete a neonatal resuscitation training session. Participants watched a training video, then provided ventilation to term and preterm manikins first without, and then with, the RFM. Clinicians completed a survey after the session and undertook a follow-up session three months later. The primary outcome was participant satisfaction with the RFM. Secondary outcomes included participants' self-assessment of face mask leak and tidal volumes when using the RFM.
Results:
Fifty clinicians completed both the initial and follow-up session. Participants reported high levels of satisfaction with the RFM for both term and preterm manikins: on a scale from 0, meaning "not at all", and 100, meaning "yes, for all resuscitations", the median response (interquartile range, IQR) was 82 (74-94) vs 81.5 (69-94.5). Levels of satisfaction were similar for less experienced and more experienced clinicians: median (IQR) 83 (77-93) vs 81 (71.5-95) respectively. When using the monitor, clinicians accurately self-assessed that they achieved leak below 30% and tidal volumes within the target range at least 80% of the time.
Conclusion:
Clinicians of all experience levels had a high level of satisfaction with a training package including a novel RFM.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...