18F-FDG PET/CT anatomic and metabolic guidance in CT-guided lung biopsies
Konstantinos Stefanidis1, Ioannis Bellos2, Elissavet Konstantelou3
1Radiology Department, King's College Hospital NHS Foundation Trust, London, UK.
Purpose:
To evaluate the role of Fluorine-18 fluorodeoxyglucose (18F-FDG) PET/CT as a metabolic guide in increasing the accuracy, diagnostic yield and safety of CT-guided percutaneous needle lung biopsy (PNB).
Methods And Materials:
Retrospective analysis of 340 consecutive patients with suspicious lung nodules, masses or extensive disease that underwent lung biopsy over a 3-year period. Patients were divided into three groups; those that had PET/CT prior to the biopsy, those that had PET-CT following the biopsy and those who did not undergo PET-CT. Correlation was made with the histopathological result.
Results:
353 PNBs were performed (median lesion size 30 mm, 7-120 mm) with overall diagnostic rate of 83.9 % (95.8 % malignant). Biopsy success rate was 88.8 % with PET-CT pre-PNB, versus 78.9 % of 175 PNB without PET-CT upfront (p < 0.01 Fisher exact test). Correct targeting to PET-CT-maximum activity area (MAA) was present in 87.1 %. Biopsy success rate was 88.8 % for PNBs targeting the PET-CT-MAA region and only 52.8 % for PNBs not targeting the PET-CT-MAA (p < 0.0001). PET-CT pre-PNB had higher rates of PET-CT-MAA targeting compared to PET-CT post PNB (91.0 % v 80.0 %, p = 0.01). The availability of PET-CT before the PNB lead to significantly increased biopsy success rates in patients with a mass (OR:7.01p = 0.004), compared to a nodule (p = 0.498) or multiple nodules (p = 0.163). Patients with a PET-CT pre-PNB underwent fewer PNB passes (mean 2.6 v 3.1, p < 0.0001 Mann Whitney U). Serious complications were less common in PET-CT pre-PNB group (4.5 % v 10.9 %, p < 0.05). Pre-PNB PET-CT performance improvement applied to all 3 radiologists and was greatest for masses and infiltrative abnormalities.
Conclusion:
Metabolic information provided by 18F-FDG PET/CT and PNB localisation to the PET-CT maximum activity region is associated with higher diagnostic biopsy rates especially in masses and appears to account for improved performance, less needle passes and complications when available pre-biopsy.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
10:53Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT
Published on: November 23, 2012
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET