Modelling electrified railway signalling misoperations during extreme space weather events in the UK
Cameron J Patterson1, James A Wild2, Ciarán D Beggan2
1Department of Physics, Lancaster University, Lancaster, LA1 4YW, UK. c.patterson2@lancaster.ac.uk.
Abstract:
Space weather has the potential to impact ground-based technologies on Earth, affecting many systems including railway signalling. This study uses a recently developed model to analyse the impact of geomagnetically induced currents on railway signalling systems in the United Kingdom during the March 1989 and October 2003 geomagnetic storms. The March 1989 storm is also scaled to estimate a 1-in-100 year and a 1-in-200 year extreme storm. Both the Glasgow to Edinburgh line, and the Preston to Lancaster section of the West Coast Main Line are modelled. No "right side" failures (when unoccupied sections appear occupied) are suggested to have occurred during either storm, and the total number of potential "wrong side" failures (when occupied sections appear clear) is low. However, the modelling indicates "right side" and "wrong side" failures are possible on both routes during the 1-in-100 year and 1-in-200 year extreme storms, with the Glasgow to Edinburgh line showing more total misoperations than the Preston to Lancaster section of the West Coast Main Line. A 1-in-100 year or 1-in-200 year extreme storm would result in misoperations over an extended period of time, with most occurring over a duration of 2-3 h either side of the peak of the storm.
Related Concept Videos
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Power System Three-Phase Short Circuits
Electromagnetic Fields
However, the observation of...
Pilot and Numeric Relaying
Electrostatic Boundary Conditions
The surface integral of an electric field is given by Gauss's law in integral form and is related to...
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...