Redox-mediated electrochemiluminescence enhancement for bead-based immunoassay
Alessandro Fracassa1, Claudio Ignazio Santo1, Emily Kerr2
1Department of Chemistry Giacomo Ciamician, University of Bologna via Selmi 2 Bologna 40126 Italy g.valenti@unibo.it.
Chemical Science
|January 19, 2024
Summary
This study investigates how iridium(iii) complexes affect electrochemiluminescence (ECL) in bead-based immunoassays. Researchers found these mediators can significantly enhance or reduce ECL signals, offering new design guidelines for improved detection.
Failed At:
2026-06-19T13:49:28.466674+00:00
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
13.1K
In 1971, Peter Perlman and Eva Engvall developed an Enzyme-linked immunosorbent assay (ELISA or EIA). ELISA differs from western blot in that the assays are conducted in microtiter plates or in vivo rather than on an absorbent membrane.
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
13.1K
Photoluminescence: Applications
402
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
402
Immunofluorescence Microscopy
10.4K
A fluorescence microscope uses fluorescent chromophores called fluorochromes, which can absorb energy from a light source and then emit this energy as visible light. Fluorochromes include naturally fluorescent substances (such as chlorophylls) and fluorescent stains that are added to the specimen to create contrast. Dyes such as Texas red and FITC are examples of fluorochromes. Other examples include the nucleic acid dyes 4’,6’-diamidino-2-phenylindole (DAPI), and acridine orange.
10.4K